Shared research memory

Evidence graph

Find earlier trials, follow the data, and see which studies reuse the same evidence.

Unavailable in this read-only snapshot.

Filter evidence
study · complete

Chilling status improved average CO₂ uptake predictions for held-out Potvin grass plants

Same 12-plant Potvin cohort and overlapping comparisons; consolidated as one method demonstration.

Current checked synthesis

Open study

Connected evidence

follows this node
New study · awaiting PI title · blocked
This node performed
bibliography.lookup · ok
This node performed
grass.acquire · ok
This node performed
grass.compare · ok
Evidence record and provenance
{
  "run": "brief-330b53f6935349cc",
  "summary": {
    "phase": "abstract",
    "assessment": "The registered comparison covered every audited plant and all 84 uptake measurements.",
    "evidence_artifact_ids": [
      "06f86d7a7c5c2679007d1ca0dc477f90f6179bc7f5a95d10053f6de8159cdc0a",
      "49a70752c8ed50fa6c348f014d00c5a6f9c75456817bde6e46467401292c4d7d",
      "79bed7244f434371649d6e9fcbacf2526db9638fff9a9a24dc889f58d3aca3ea",
      "c9110e613fcc2680551a8f5a122ecb73e6197a3ea36a3eef7833c781ded63716",
      "fe761ab3273141efba4d3d95d66af442442d203b430d98db39df401bc90c5fa0"
    ],
    "limitations": [
      "With three plants per origin and treatment combination, the gain is imprecisely estimated and its generalizability requires an independent cohort. This predictive comparison cannot establish a causal effect of chilling."
    ],
    "requested_operations": [],
    "disposition": "accept",
    "continue_on_current_data": true,
    "title": "Chilling status improved average CO₂ uptake predictions for held-out Potvin grass plants",
    "objective": "We asked whether chilling status improves prediction of a plant’s CO₂ uptake after accounting for its origin and the natural logarithm of CO₂ concentration.",
    "methods": "Holding out one whole plant at a time, the registered analysis fitted unweighted ordinary least squares models with an intercept, origin and log CO₂ concentration, then repeated each fit with a shared additive chilling term. We compared mean absolute error (MAE) across the seven concentrations for each held-out plant and weighted plants equally.",
    "results": "Adding chilling status reduced mean MAE from 5.346 to 4.272 µmol m⁻² s⁻¹, a paired reduction of 1.075 µmol m⁻² s⁻¹. MAE fell for 9 of 12 plants and rose most for Qc2, from 3.914 to 6.211 µmol m⁻² s⁻¹, an increase of 2.297 µmol m⁻² s⁻¹.",
    "interpretation": "Chilling status improved uptake predictions on average within the Potvin design. All three plants with larger errors came from Quebec, suggesting that a shared chilling term may fit the two origins differently.",
    "next_question": "On the same whole-plant holdouts, does adding an origin-by-chilling interaction to the additive model further reduce equal-plant MAE in an exploratory comparison?"
  },
  "url": "/brief/brief-330b53f6935349cc"
}