Evidence graph
Find earlier trials, follow the data, and see which studies reuse the same evidence.
Unavailable in this read-only snapshot.
Log CO₂ concentration lowered average uptake prediction error for held-out Potvin plants after adjustment for origin and chilling
Same 12-plant Potvin cohort and overlapping comparisons; consolidated as one method demonstration.
Connected evidence
This node concluded
Log CO₂ concentration lowered average uptake prediction error for held-out Potvin plants after adjustment for origin and chilling · answered
Log CO₂ concentration lowered average uptake prediction error for held-out Potvin plants after adjustment for origin and chilling · answered
This node continues
Does log CO₂ concentration predict uptake more accurately than linear concentration for a held-out Potvin grass plant? · superseded
Does log CO₂ concentration predict uptake more accurately than linear concentration for a held-out Potvin grass plant? · superseded
This node performed
Which trial records from brief-4415fb42486d481a contain the plant-level errors for linear and log CO₂ concentration with additive origin and chilling? · ok
Which trial records from brief-4415fb42486d481a contain the plant-level errors for linear and log CO₂ concentration with additive origin and chilling? · ok
This node performed
Can the lab graph locate the reviewer’s cited trial containing held-out plant errors for the model with linear CO₂ concentration, origin and chilling? · ok
Can the lab graph locate the reviewer’s cited trial containing held-out plant errors for the model with linear CO₂ concentration, origin and chilling? · ok
This node performed
Which trial and held-out prediction result did the original run cite for adding geographic origin to log CO₂ concentration and chilling? · ok
Which trial and held-out prediction result did the original run cite for adding geographic origin to log CO₂ concentration and chilling? · ok
This node performed
Which columns identify each plant, its origin and chilling treatment, the CO₂ concentration and measured uptake in the registered CO2 table? · ok
Which columns identify each plant, its origin and chilling treatment, the CO₂ concentration and measured uptake in the registered CO2 table? · ok
This node performed
With additive origin and chilling in both models, what is the linear-minus-log uptake MAE for each of the 12 held-out plants and their equally weighted mean in µmol m⁻² s⁻¹? · ok
With additive origin and chilling in both models, what is the linear-minus-log uptake MAE for each of the 12 held-out plants and their equally weighted mean in µmol m⁻² s⁻¹? · ok
This node performed
Which archived Potvin trial reports the adjusted linear-model errors that the reviewer attributes to observation_10.json of brief-4415fb42486d481a? · ok
Which archived Potvin trial reports the adjusted linear-model errors that the reviewer attributes to observation_10.json of brief-4415fb42486d481a? · ok
This node performed
What augmented MAE did historical observation_10.json report for each held-out plant under conc,origin,chill, and does each value match the current linear-model MAE for that plant? · ok
What augmented MAE did historical observation_10.json report for each held-out plant under conc,origin,chill, and does each value match the current linear-model MAE for that plant? · ok
This node performed
Does each held-out plant’s baseline MAE in historical observation_6.json match its adjusted log-model MAE in the current potvin_compare receipt? · ok
Does each held-out plant’s baseline MAE in historical observation_6.json match its adjusted log-model MAE in the current potvin_compare receipt? · ok
This node performed
Does the registered receipt resolve the adjusted concentration-scale comparison after checking both archived error series by plant ID? · ok
Does the registered receipt resolve the adjusted concentration-scale comparison after checking both archived error series by plant ID? · ok
revisits this node
Does log CO₂ concentration improve held-out plant uptake predictions after adjustment for origin and chilling? · superseded
Does log CO₂ concentration improve held-out plant uptake predictions after adjustment for origin and chilling? · superseded
This node revisits
Which measured features or response shapes improve prediction of CO2 uptake for another plant from the same experimental design? · archived
Which measured features or response shapes improve prediction of CO2 uptake for another plant from the same experimental design? · archived
revisits this node
Log CO₂ concentration lowered average uptake prediction error for held-out Potvin plants after adjustment for origin and chilling · complete
Log CO₂ concentration lowered average uptake prediction error for held-out Potvin plants after adjustment for origin and chilling · complete
Evidence record and provenance
{
"run": "brief-ae69c3ad445656b3",
"summary": {
"phase": "research_review",
"title": "Log CO₂ concentration lowered average uptake prediction error for held-out Potvin plants after adjustment for origin and chilling",
"objective": "The original question asked whether adding geographic origin improved uptake prediction given log CO₂ concentration and chilling. The reviewer asked whether changing the concentration scale improved prediction with origin and chilling in both models.",
"methods": "The registered potvin_compare runner used the 84 uptake measurements in the R datasets table CO2. Each ordinary least-squares fit held out one whole plant. Both models used a common concentration slope and additive origin and chilling terms. The baseline used conc,origin,chill and the comparison used log_conc,origin,chill. Only the concentration predictor took a natural logarithm. The runner averaged absolute errors on the measured uptake scale across each plant’s seven concentrations, then gave all 12 plants equal weight.",
"results": "The archived review (finding:brief-3bb15cea899b4e52, citing trial:brief-3bb15cea899b4e52:grass_result.json) reported that adding origin to log_conc,chill lowered mean absolute error (MAE). An earlier concentration-only comparison also favored log concentration (trial:brief-4415fb42486d481a:observation_5.json). In the adjusted same-data reanalysis, equal-plant MAE was 5.119 µmol m⁻² s⁻¹ with linear concentration and 4.272 µmol m⁻² s⁻¹ with log concentration. The runner reported a mean paired reduction of 0.847 µmol m⁻² s⁻¹. The paired differences (linear MAE minus log MAE, µmol m⁻² s⁻¹) were Mc1 -0.326, Mc2 -1.42e-11, Mc3 -0.775, Mn1 +1.329, Mn2 +1.586, Mn3 +1.206, Qc1 +1.371, Qc2 +1.285, Qc3 +1.574, Qn1 +0.137, Qn2 +1.258, Qn3 +1.523.",
"interpretation": "With origin and chilling held fixed, using log concentration improved average prediction on these plants. Linear concentration gave lower error for Mc1 and Mc3. The two predictions had effectively equal MAE for Mc2.",
"assessment": "Accept closure. Searches in observations 1, 2 and 6 located prior records. Observation 3 retrieved the original reviewed finding. The CO2 table hash in observation 4 matches the archived table record. In observation 5, every baseline MAE matches the historical augmented MAE from trial:brief-4415fb42486d481a:observation_10.json, and every comparison MAE matches the historical baseline MAE from trial:brief-4415fb42486d481a:observation_6.json, by plant ID. Observations 7 and 8 retrieved those receipts. Both series cover every plant, and the direct receipt supplies all requested differences and their equal-plant mean. Observation 9 closed the investigation.",
"limitations": [
"The runner supplied point estimates only. The training folds overlap, and just three plants represent each origin-by-chilling group. Selection of this comparison after earlier analyses of the same plants makes it exploratory. Predictive performance in an independent cohort remains unknown."
],
"evidence_artifact_ids": [
"59b9c6a2e7e8b9b8800272401e32eab142da05fa6c295f2286685cffbc772842",
"a18693170a322b7ba50951814e3077d6ad761df38261c5d83bcb4e955210813c",
"7256949d94e1093f4755a113526c63463a6e9b2aa86f7a4dc327452d31f293c8",
"23ce41b5c9702bbb33eaa6f2f741a2f2c57f30785cd57b60d44b6ef72528b711",
"973007f2ca98bf77524fea1151a646580d4c930ebd8ea63e39ad9e34141acdf4",
"35a1f30c4bd412144a941de22aed88bf4275780ebd9d0a645fa6f1654f848dba",
"5fdb99e84f8405d5f0ae6b0c802649eb12430b513bbeff66f451258bc6160b98",
"08620425aa3723b53d0b07cd0d8c6099774573cfb37fff3a9ea5b9b706d99fa0",
"ef262427040b7918dcd0f930ff8378e12704a30151e1bfe41fcfa5605adb4380",
"c6be8f2e3571e9febb9b8d33cb46f51849819f9a919cd5f30b17ded0ed64eb03",
"4222bab6be218a3161b105a0e3605aaeaf4d982df03d66eb39518dd0023384a6"
],
"disposition": "accept",
"outcome": "answered",
"remaining_evidence": "",
"continue_on_current_data": false,
"requested_operations": [],
"next_question": "None. The adjusted comparison completes the reviewer’s request."
},
"url": "/brief/brief-ae69c3ad445656b3"
}