Historical execution record
Same 12-plant Potvin cohort and overlapping comparisons; consolidated as one method demonstration.
Chilling status improved CO₂ uptake predictions for 9 of 12 held-out Potvin grass plants
Summary
For a whole plant held out from the Potvin cohort, knowing its chilling status improved prediction on average. The gain varied among plants and does not establish how chilling changes uptake causally.
Results
Adding chilling status reduced equal-plant mean absolute error (MAE) from 5.346 to 4.272 µmol m⁻² s⁻¹. The receipt reports a baseline-minus-augmented difference of +1.075 µmol m⁻² s⁻¹ (grass_result.json, /mae). MAE fell for 9 of 12 plants (/per_plant). Qc2 had the largest increase, from 3.914 to 6.211 µmol m⁻² s⁻¹, a rise of 2.297 µmol m⁻² s⁻¹ (/per_plant/7).
What the results mean
For a whole plant held out from the Potvin cohort, knowing its chilling status improved prediction on average. The gain varied among plants and does not establish how chilling changes uptake causally.
Limitations
- Each origin and chilling combination contained three plants. The seven concentration measurements on each plant are repeated observations. The receipt gives paired prediction errors and provides no uncertainty interval for the average gain.
- All folds draw from the same cohort. Whether the gain recurs in independently sampled plants remains open.
Research question & methods
Objective
Does knowing whether a plant was chilled improve prediction of its CO₂ uptake after accounting for geographic origin and the natural log of CO₂ concentration?
Methods
We verified the specialist’s handback against the registered chilling_information comparison in grass_result.json. The source manifest and plant audit identify the same grass_co2.csv version (SHA-256 0c16fc00f276b0981a0d9f8800de62524acda32f66d7a0f7b96e0806c04a7b29). In each fold, the runner fitted two unweighted ordinary least squares models on 11 plants and predicted uptake at all seven concentrations for the omitted plant. Both models included an intercept, origin (Quebec or Mississippi) and a common slope for natural log concentration. The augmented model added a shared chilling effect. The runner averaged absolute errors on the original uptake scale within each plant, then weighted the plant means equally.
Original research request
In the Potvin grass dataset, does knowing whether a plant was chilled improve CO₂ uptake predictions after accounting for its origin and log CO₂ concentration? Hold out one whole plant at a time. Report how many plants benefited and identify the plant whose prediction got worse by the largest amount.
Evidence & execution steps
View execution activity · Explore connected evidence
Research outcome
answered
Extended investigation
Does adding chilling status to origin and natural log CO₂ concentration also lower equal-plant mean absolute error (MAE) in an independently sampled cohort measured under the Potvin design?
The primary comparison is resolved. Adding chilling status reduced equal-plant MAE from 5.346 to 4.272 µmol m⁻² s⁻¹ across whole-plant holdouts. Nine of 12 plants benefited. Qc2 had the largest increase in MAE, from 3.914 to 6.211 µmol m⁻² s⁻¹. The source manifest and audit identify a single cohort of 12 plants. The registered instruments have no independent plant measurements on which to evaluate the follow-up.
Evidence and limitations
- Each origin and chilling combination contained three plants. The seven concentration measurements on each plant are repeated observations. The receipt gives paired prediction errors and provides no uncertainty interval for the average gain.
- All folds draw from the same cohort. Whether the gain recurs in independently sampled plants remains open.
Artifact references
abstract.jsond595b07c7b2d29c2f59ba5bd3aa9bf229bf6e58136f60d06d7b3755975cbea1d
assignment_1.jsond1d1a172cbc921f34b3fe2eb08125760b824a00e67f13b8c9eeb58099050c1bc
brief.json454663ad476ba28b46a251469514306d42db63b4cef7e6f0df47a3f98fd2a7c1
extension.jsona201836309db782ee4bceb56ea31f2d1b5a7ce50b5a3922d9e0b9cce96296f6d
handoff_1.jsonbc2d3d902abfb2344c4c301c43da50adaefce35017f36fb076a4135403460f5e
import_0dde2294702c5459f8631edb31041a8cc798270da6701f3a0ad7f0482f8a0789.json0dde2294702c5459f8631edb31041a8cc798270da6701f3a0ad7f0482f8a0789
import_456b55b7887892b724fa44e56e0bfeb6b17177b466578480848d5ba2c04df580.json456b55b7887892b724fa44e56e0bfeb6b17177b466578480848d5ba2c04df580
import_62db72a457c9b66054ba3431617107edc2aab76cb0ce086fff77fa930bbcdea4.json62db72a457c9b66054ba3431617107edc2aab76cb0ce086fff77fa930bbcdea4
import_6ecf58e48c0aa7822f34d2e1337bf7f721767ad14114828616ac28b5ab033169.json6ecf58e48c0aa7822f34d2e1337bf7f721767ad14114828616ac28b5ab033169
import_9572f1565c7091f6385aad4410c0a7b8e416d6b038148c0f894f9c4bf5d76085.json9572f1565c7091f6385aad4410c0a7b8e416d6b038148c0f894f9c4bf5d76085
import_bfaf24cd5b7e3cc7c92ceb46eff2219f0c26c7053c6792d07e3c4452d5293543.jsonbfaf24cd5b7e3cc7c92ceb46eff2219f0c26c7053c6792d07e3c4452d5293543
import_c49ffa8bd3f21e2190d0ce49322e8eded34a380583418c4cf9711d1df6354b92.jsonc49ffa8bd3f21e2190d0ce49322e8eded34a380583418c4cf9711d1df6354b92
import_c9110e613fcc2680551a8f5a122ecb73e6197a3ea36a3eef7833c781ded63716.jsonc9110e613fcc2680551a8f5a122ecb73e6197a3ea36a3eef7833c781ded63716
import_f5d2662fa37771ac133c3078a26dbc18b0b3543b911a872e9c4e1f3cec804ced.jsonf5d2662fa37771ac133c3078a26dbc18b0b3543b911a872e9c4e1f3cec804ced
import_fd1f998b9abb3b53be669672dbc29375fd876624f926f27e3a4d5e2e61933ee6.jsonfd1f998b9abb3b53be669672dbc29375fd876624f926f27e3a4d5e2e61933ee6
import_fe761ab3273141efba4d3d95d66af442442d203b430d98db39df401bc90c5fa0.jsonfe761ab3273141efba4d3d95d66af442442d203b430d98db39df401bc90c5fa0
protocol.json456b55b7887892b724fa44e56e0bfeb6b17177b466578480848d5ba2c04df580
research_plan.jsonf43a5f9a23eb5076ce2b7bd28d00174e82720941a2dc32f8f490a2f0c512c8de
source_manifest.jsonbfaf24cd5b7e3cc7c92ceb46eff2219f0c26c7053c6792d07e3c4452d5293543
team_setup.json4f0a350fe211bace96b6395c0259b2d7cf9a039919a47a889bc9c36f2b7a0b51
Verified against 13 accepted tasks, 7 verified Codex turns and 0 estimator fits.