Historical execution record
Same 12-plant Potvin cohort and overlapping comparisons; consolidated as one method demonstration.
Chilling status improved CO₂ uptake predictions for 9 of 12 held-out Potvin grass plants
Summary
Knowing chilling status improved prediction on average in this experiment. Allowing a separate chilling effect for each origin gave a smaller additional gain. Qc2, which fared worst when the shared chilling term was added, had lower error when the interaction was included.
Results
The archived reviewed finding reports that adding chilling status reduced equal-plant MAE from 5.346 to 4.272 µmol m⁻² s⁻¹, a paired reduction of 1.075 µmol m⁻² s⁻¹. Nine of 12 plants had lower MAE. Qc2 had the largest increase, from 3.914 to 6.211 µmol m⁻² s⁻¹, up 2.297 µmol m⁻² s⁻¹. In the extension, the current runner reported MAE of 4.272 with shared chilling and 4.088 µmol m⁻² s⁻¹ with origin-specific chilling, a paired reduction of 0.183 µmol m⁻² s⁻¹. Seven plants improved and five worsened. The plant-level reductions (shared minus origin-specific MAE, µmol m⁻² s⁻¹) were Mc1 −1.121, Mc2 +1.152, Mc3 −0.348, Mn1 +1.198, Mn2 +0.811, Mn3 −0.675, Qc1 −1.064, Qc2 +1.448, Qc3 +0.877, Qn1 +1.430, Qn2 +0.265 and Qn3 −1.774. Each plant carries equal weight in the reported mean reduction.
What the results mean
Knowing chilling status improved prediction on average in this experiment. Allowing a separate chilling effect for each origin gave a smaller additional gain. Qc2, which fared worst when the shared chilling term was added, had lower error when the interaction was included.
Limitations
- The packet supplies the reviewed finding and its trial citation for the original comparison. The original plant-level calculation receipt was not retrieved in this run.
- Neither comparison supplies an uncertainty interval. Each origin–treatment group contained three plants, and the training folds overlap.
- The Quebec error pattern motivated the interaction comparison on the same plants. Its gain is exploratory. Generalization requires independent plants, and predictive errors alone cannot establish a causal chilling effect.
Research question & methods
Objective
Determine whether chilling status improves uptake prediction beyond plant origin and log CO₂ concentration, count the plants with lower prediction error, and identify the largest deterioration. The extension asked whether allowing the chilling effect to differ between Quebec and Mississippi further improves prediction.
Methods
The source was the R datasets CO2 table (SHA-256 a24abfa3686f7489a84845b4d6823e08af21f5f94b6455404bbdbbe2f22e7571), with 84 uptake measurements from 12 plants. Unweighted least-squares models with intercepts held out one whole plant per fold. Mean absolute error (MAE) was averaged across its seven concentrations, then across plants with equal weight. The original comparison added chill to log_conc,origin, where log_conc is natural log CO₂ concentration. The extension compared log_conc,origin,chill with log_conc,origin,chill,origin_chill on the same folds. Errors are on the uptake scale.
Original research request
In the Potvin grass dataset, does knowing whether a plant was chilled improve CO₂ uptake predictions after accounting for its origin and log CO₂ concentration? Hold out one whole plant at a time. Report how many plants benefited and identify the plant whose prediction got worse by the largest amount.
Evidence & execution steps
View execution activity · Explore connected evidence
Research outcome
answered
Extended investigation
After accounting for origin and log CO₂ concentration, does allowing the chilling effect to differ between Quebec and Mississippi reduce equal-plant mean absolute error in uptake predictions compared with a shared chilling effect when each Potvin plant is held out in turn?
The reviewed trial found that adding a shared chilling term reduced equal-plant mean absolute error (MAE) by 1.075 µmol m⁻² s⁻¹. Nine of 12 plants benefited. All three increases occurred in Quebec plants, with the largest increase in Qc2 (2.297 µmol m⁻² s⁻¹). This pattern motivates testing whether estimating a separate chilling effect for each origin improves prediction enough to justify the extra parameter. The registered potvin_compare runner can use the CO2 table to compare baseline log_conc,origin,chill with augmented log_conc,origin,chill,origin_chill on identical whole-plant holdouts. A positive baseline-minus-augmented difference in equal-plant MAE would favor the origin-specific model. The paired plant errors would show which plants contributed to that difference.
Evidence and limitations
- The packet supplies the reviewed finding and its trial citation for the original comparison. The original plant-level calculation receipt was not retrieved in this run.
- Neither comparison supplies an uncertainty interval. Each origin–treatment group contained three plants, and the training folds overlap.
- The Quebec error pattern motivated the interaction comparison on the same plants. Its gain is exploratory. Generalization requires independent plants, and predictive errors alone cannot establish a causal chilling effect.
Research steps
Which archived Potvin trial provides paired errors for held-out plants when chilling status is added to origin and log CO₂ concentration?
lab_search · ok
{
"matches": [
{
"artifact_id": "c15d133911a67e3bf3f0deec29ec88f17f3044fb895ca4b0b71e0224b6d4d18d",
"id": "finding:brief-37b5663a02e0420e",
"kind": "finding",
"label": "Recheck whether chilling status improves prediction of CO2 uptake for a held-out plant in the Potvin grass dataset, controlling for origin and log concentration. Report the paired errors.",
"run": "brief-37b5663a02e0420e",
"state": "answered",
"summary": "{'phase': 'research_review', 'title': 'Chilling status reduced average prediction error for held-out Potvin grass plants', 'objective': 'Recheck whether chilling status improves CO₂ uptake prediction for a held-out Echinochloa crus-galli plant after accounting for origin and log concentration, and report the paired errors. The extension asked whether the chilled-minus-nonchilled difference in mean uptake varied by origin at 350 µL/L CO₂.', 'assessment': 'Accept closure. The lab search located finding:brief-d8f1827a54544274, and the lab read retrieved its reviewed summary and link to trial:brief-d8f1827a54544274:grass_result.json. The table inspection confirmed the plants, predictors and uptake endpoint. The current potvin_compare receipt supplies every requested error pair and reproduces the earlier aggregate errors at the reported precision. After the first finish action, the extension selected a single concentration. The contrast receipt directly answers its between-origin question. The final finish action recorded closure.', 'methods': 'The registered potvin_compare runner used the R datasets CO2 table (table SHA-256 a24abfa3686f7489a84845b4d6823e08af21f5f94b6455404bbdbbe2f22e7571). It held out each whole plant in turn and fit two unweighted ordinary least squares models with intercepts to the other plants. The baseline used log_conc,origin (natural log CO₂ concentration and plant origin). The augmented model used log_conc,origin,chill, adding a shared chilling main effect. Each plant’s mean absolute error (MAE) averaged its seven concentration-specific errors. Each plan"
},
{
"artifact_id": null,
"id": "study:brief-37b5663a02e0420e",
"kind": "study",
"label": "Recheck whether chilling status improves prediction of CO2 uptake for a held-out plant in the Potvin grass dataset, controlling for origin and log concentration. Report the paired errors.",
"run": "brief-37b5663a02e0420e",
"state": "complete",
"summary": "{'phase': 'research_review', 'title': 'Chilling status reduced average prediction error for held-out Potvin grass plants', 'objective': 'Recheck whether chilling status improves CO₂ uptake prediction for a held-out Echinochloa crus-galli plant after accounting for origin and log concentration, and report the paired errors. The extension asked whether the chilled-minus-nonchilled difference in mean uptake varied by origin at 350 µL/L CO₂.', 'assessment': 'Accept closure. The lab search located finding:brief-d8f1827a54544274, and the lab read retrieved its reviewed summary and link to trial:brief-d8f1827a54544274:grass_result.json. The table inspection confirmed the plants, predictors and uptake endpoint. The current potvin_compare receipt supplies every requested error pair and reproduces the earlier aggregate errors at the reported precision. After the first finish action, the extension selected a single concentration. The contrast receipt directly answers its between-origin question. The final finish action recorded closure.', 'methods': 'The registered potvin_compare runner used the R datasets CO2 table (table SHA-256 a24abfa3686f7489a84845b4d6823e08af21f5f94b6455404bbdbbe2f22e7571). It held out each whole plant in turn and fit two unweighted ordinary least squares models with intercepts to the other plants. The baseline used log_conc,origin (natural log CO₂ concentration and plant origin). The augmented model used log_conc,origin,chill, adding a shared chilling main effect. Each plant’s mean absolute error (MAE) averaged its seven concentration-specific errors. Each plan"
},
{
"artifact_id": "3f057336bca7add0236c8f18c98cd2b16e0ce8d95435fb4a16ba4229e2988f74",
"id": "finding:brief-d8f1827a54544274",
"kind": "finding",
"label": "Recheck whether chilling status improves prediction of CO2 uptake for a held-out plant in the Potvin grass dataset, controlling for origin and log concentration. Report the paired errors.",
"run": "brief-d8f1827a54544274",
"state": "reviewed",
"summary": "{'phase': 'abstract', 'assessment': 'The runner used the prespecified model pair and reported paired errors for every audited plant. The equal-plant means agree with the individual errors.', 'evidence_artifact_ids': ['d49b2d55cc6b8bdcb488967c16ab6196d22f69fd325dc798e979cb0b038f122c', 'b1a08f3d798a2c00fa21d6f2e72f8490cd3306ca4e3d402cf7aca479e54e7c13', '4170db3d2d1c5a9b1733dd8014e446df60666af7eb22fab3e5b8cfb463528f1f', '54bc64e54e9624713d81283086c0fdb6992eba1926e1adab38ece25b324d3fc1', 'c5b34cc2631867fd84f57ea71011999624c7a0a897023ad971b1885c252949d8'], 'limitations': ['Only three plants represented each origin-by-treatment group, and the training folds overlapped. Performance on an independent cohort remains unknown.'], 'requested_operations': [], 'disposition': 'accept', 'continue_on_current_data': False, 'title': 'Chilling status improved average prediction of CO₂ uptake in held-out Potvin grass plants', 'objective': 'We asked whether chilling status improved prediction of CO₂ uptake in a held-out Echinochloa crus-galli plant after accounting for origin and CO₂ concentration.', 'methods': 'Leaving out one whole plant at a time, we compared unweighted ordinary least squares models with an intercept, origin and natural log CO₂ concentration, adding a chilling main effect to the second model. We calculated mean absolute error (MAE) across seven concentrations for each held-out plant and averaged MAE equally across plants.', 'results': 'Adding chilling status reduced equal-plant MAE from 5.346 to 4.272 µmol m⁻² s⁻¹, a paired mean reduction of 1.075 µmol m⁻² s⁻¹. MAE fell for a"
},
{
"artifact_id": null,
"id": "study:brief-d8f1827a54544274",
"kind": "study",
"label": "Recheck whether chilling status improves prediction of CO2 uptake for a held-out plant in the Potvin grass dataset, controlling for origin and log concentration. Report the paired errors.",
"run": "brief-d8f1827a54544274",
"state": "complete",
"summary": "{'phase': 'abstract', 'assessment': 'The runner used the prespecified model pair and reported paired errors for every audited plant. The equal-plant means agree with the individual errors.', 'evidence_artifact_ids': ['d49b2d55cc6b8bdcb488967c16ab6196d22f69fd325dc798e979cb0b038f122c', 'b1a08f3d798a2c00fa21d6f2e72f8490cd3306ca4e3d402cf7aca479e54e7c13', '4170db3d2d1c5a9b1733dd8014e446df60666af7eb22fab3e5b8cfb463528f1f', '54bc64e54e9624713d81283086c0fdb6992eba1926e1adab38ece25b324d3fc1', 'c5b34cc2631867fd84f57ea71011999624c7a0a897023ad971b1885c252949d8'], 'limitations': ['Only three plants represented each origin-by-treatment group, and the training folds overlapped. Performance on an independent cohort remains unknown.'], 'requested_operations': [], 'disposition': 'accept', 'continue_on_current_data': False, 'title': 'Chilling status improved average prediction of CO₂ uptake in held-out Potvin grass plants', 'objective': 'We asked whether chilling status improved prediction of CO₂ uptake in a held-out Echinochloa crus-galli plant after accounting for origin and CO₂ concentration.', 'methods': 'Leaving out one whole plant at a time, we compared unweighted ordinary least squares models with an intercept, origin and natural log CO₂ concentration, adding a chilling main effect to the second model. We calculated mean absolute error (MAE) across seven concentrations for each held-out plant and averaged MAE equally across plants.', 'results': 'Adding chilling status reduced equal-plant MAE from 5.346 to 4.272 µmol m⁻² s⁻¹, a paired mean reduction of 1.075 µmol m⁻² s⁻¹. MAE fell for a"
},
{
"artifact_id": "f5d2662fa37771ac133c3078a26dbc18b0b3543b911a872e9c4e1f3cec804ced",
"id": "finding:brief-330b53f6935349cc",
"kind": "finding",
"label": "In the Potvin grass dataset, does knowing whether a plant was chilled improve CO₂ uptake predictions after accounting for its origin and log CO₂ concentration? Hold out one whole plant at a time. Report how many plants benefited and identify the plant whose prediction got worse by the largest amount.",
"run": "brief-330b53f6935349cc",
"state": "reviewed",
"summary": "{'phase': 'abstract', 'assessment': 'The registered comparison covered every audited plant and all 84 uptake measurements.', 'evidence_artifact_ids': ['06f86d7a7c5c2679007d1ca0dc477f90f6179bc7f5a95d10053f6de8159cdc0a', '49a70752c8ed50fa6c348f014d00c5a6f9c75456817bde6e46467401292c4d7d', '79bed7244f434371649d6e9fcbacf2526db9638fff9a9a24dc889f58d3aca3ea', 'c9110e613fcc2680551a8f5a122ecb73e6197a3ea36a3eef7833c781ded63716', 'fe761ab3273141efba4d3d95d66af442442d203b430d98db39df401bc90c5fa0'], 'limitations': ['With three plants per origin and treatment combination, the gain is imprecisely estimated and its generalizability requires an independent cohort. This predictive comparison cannot establish a causal effect of chilling.'], 'requested_operations': [], 'disposition': 'accept', 'continue_on_current_data': True, 'title': 'Chilling status improved average CO₂ uptake predictions for held-out Potvin grass plants', 'objective': 'We asked whether chilling status improves prediction of a plant’s CO₂ uptake after accounting for its origin and the natural logarithm of CO₂ concentration.', 'methods': 'Holding out one whole plant at a time, the registered analysis fitted unweighted ordinary least squares models with an intercept, origin and log CO₂ concentration, then repeated each fit with a shared additive chilling term. We compared mean absolute error (MAE) across the seven concentrations for each held-out plant and weighted plants equally.', 'results': 'Adding chilling status reduced mean MAE from 5.346 to 4.272 µmol m⁻² s⁻¹, a paired reduction of 1.075 µmol m⁻² s⁻¹. MAE fell for 9 of"
},
{
"artifact_id": null,
"id": "study:brief-330b53f6935349cc",
"kind": "study",
"label": "In the Potvin grass dataset, does knowing whether a plant was chilled improve CO₂ uptake predictions after accounting for its origin and log CO₂ concentration? Hold out one whole plant at a time. Report how many plants benefited and identify the plant whose prediction got worse by the largest amount.",
"run": "brief-330b53f6935349cc",
"state": "complete",
"summary": "{'phase': 'abstract', 'assessment': 'The registered comparison covered every audited plant and all 84 uptake measurements.', 'evidence_artifact_ids': ['06f86d7a7c5c2679007d1ca0dc477f90f6179bc7f5a95d10053f6de8159cdc0a', '49a70752c8ed50fa6c348f014d00c5a6f9c75456817bde6e46467401292c4d7d', '79bed7244f434371649d6e9fcbacf2526db9638fff9a9a24dc889f58d3aca3ea', 'c9110e613fcc2680551a8f5a122ecb73e6197a3ea36a3eef7833c781ded63716', 'fe761ab3273141efba4d3d95d66af442442d203b430d98db39df401bc90c5fa0'], 'limitations': ['With three plants per origin and treatment combination, the gain is imprecisely estimated and its generalizability requires an independent cohort. This predictive comparison cannot establish a causal effect of chilling.'], 'requested_operations': [], 'disposition': 'accept', 'continue_on_current_data': True, 'title': 'Chilling status improved average CO₂ uptake predictions for held-out Potvin grass plants', 'objective': 'We asked whether chilling status improves prediction of a plant’s CO₂ uptake after accounting for its origin and the natural logarithm of CO₂ concentration.', 'methods': 'Holding out one whole plant at a time, the registered analysis fitted unweighted ordinary least squares models with an intercept, origin and log CO₂ concentration, then repeated each fit with a shared additive chilling term. We compared mean absolute error (MAE) across the seven concentrations for each held-out plant and weighted plants equally.', 'results': 'Adding chilling status reduced mean MAE from 5.346 to 4.272 µmol m⁻² s⁻¹, a paired reduction of 1.075 µmol m⁻² s⁻¹. MAE fell for 9 of"
},
{
"artifact_id": "978c88c6616805539bee779366735fb31c8ac4fe6be825f67257ca3e9809c38e",
"id": "finding:brief-ebc0791811094113",
"kind": "finding",
"label": "Run a two-part investigation on Potvin's grass plants. First compare a common chilling effect against an origin-specific chilling effect, controlling for log CO2. Then test whether adding origin to linear CO2 concentration alone improves prediction for another plant. Use the registered plant-held-out error in both comparisons. After these two results, identify which claim requires an independent sample.",
"run": "brief-ebc0791811094113",
"state": "answered",
"summary": "{'phase': 'research_review', 'title': 'Origin and chilling in predictions of CO₂ uptake for held-out Potvin grass plants', 'objective': 'Does allowing the chilling effect to vary by origin lower prediction error after adjustment for log CO₂ concentration? Does adding origin to linear CO₂ concentration alone lower error for a held-out plant? Which claim requires an independent sample?', 'methods': 'Both archived ordinary least-squares comparisons used all 84 uptake measurements in the R datasets table CO2. Each fit held out one whole plant. The score averaged absolute errors across its seven concentrations, then gave each of the 12 plants equal weight. The first pair used log_conc,origin,chill with and without the added origin_chill interaction. The second compared conc with conc,origin, allowing origin-specific intercepts at a common linear slope and omitting chilling from both models. The extension used potvin_compare on the same folds with log_conc,origin,chill,origin_curve as baseline and log_conc,origin,chill,origin_curve,origin_chill as the augmented model. Only the concentration predictor was log-transformed in the chilling comparisons. All errors are on the uptake scale in µmol m⁻² s⁻¹.', 'results': 'With a shared log-concentration slope, the archived chilling trial reported mean absolute errors of 4.272 for common chilling and 4.088 for origin-specific chilling, with a reported reduction of 0.183 µmol m⁻² s⁻¹. Error fell for seven plants and rose for five (trial:brief-d503a5b597b143dc:grass_result.json). In the separate linear-concentration trial, adding origin redu"
},
{
"artifact_id": null,
"id": "study:brief-ebc0791811094113",
"kind": "study",
"label": "Run a two-part investigation on Potvin's grass plants. First compare a common chilling effect against an origin-specific chilling effect, controlling for log CO2. Then test whether adding origin to linear CO2 concentration alone improves prediction for another plant. Use the registered plant-held-out error in both comparisons. After these two results, identify which claim requires an independent sample.",
"run": "brief-ebc0791811094113",
"state": "complete",
"summary": "{'phase': 'research_review', 'title': 'Origin and chilling in predictions of CO₂ uptake for held-out Potvin grass plants', 'objective': 'Does allowing the chilling effect to vary by origin lower prediction error after adjustment for log CO₂ concentration? Does adding origin to linear CO₂ concentration alone lower error for a held-out plant? Which claim requires an independent sample?', 'methods': 'Both archived ordinary least-squares comparisons used all 84 uptake measurements in the R datasets table CO2. Each fit held out one whole plant. The score averaged absolute errors across its seven concentrations, then gave each of the 12 plants equal weight. The first pair used log_conc,origin,chill with and without the added origin_chill interaction. The second compared conc with conc,origin, allowing origin-specific intercepts at a common linear slope and omitting chilling from both models. The extension used potvin_compare on the same folds with log_conc,origin,chill,origin_curve as baseline and log_conc,origin,chill,origin_curve,origin_chill as the augmented model. Only the concentration predictor was log-transformed in the chilling comparisons. All errors are on the uptake scale in µmol m⁻² s⁻¹.', 'results': 'With a shared log-concentration slope, the archived chilling trial reported mean absolute errors of 4.272 for common chilling and 4.088 for origin-specific chilling, with a reported reduction of 0.183 µmol m⁻² s⁻¹. Error fell for seven plants and rose for five (trial:brief-d503a5b597b143dc:grass_result.json). In the separate linear-concentration trial, adding origin redu"
},
{
"artifact_id": "4b00f2fc4011cd799caa6efe0bc81224c4ac172041d0bf06ae6f7892701c6bc4",
"id": "finding:brief-d503a5b597b143dc",
"kind": "finding",
"label": "Run a two-part investigation on Potvin's grass plants. First compare a common chilling effect against an origin-specific chilling effect, controlling for log CO2. Then test whether adding origin to linear CO2 concentration alone improves prediction for another plant. Use the registered plant-held-out error in both comparisons. After these two results, identify which claim requires an independent sample.",
"run": "brief-d503a5b597b143dc",
"state": "reviewed",
"summary": "{'phase': 'abstract', 'title': 'Predicting CO₂ uptake in Potvin’s grass plants with origin-specific chilling effects', 'objective': 'We asked whether allowing the chilling effect to vary by origin improves uptake prediction after adjustment for log CO₂ concentration. A second question asked whether origin improves prediction when linear CO₂ concentration is the sole baseline predictor.', 'methods': 'We compared two prespecified least-squares models on all 84 measurements from 12 plants, holding out each plant in turn and averaging its absolute errors across concentrations before weighting plants equally. Both models included log CO₂ concentration, origin and chilling, and the second added an origin-by-chilling interaction.', 'results': 'Mean absolute error fell from 4.272 to 4.088 µmol m⁻² s⁻¹ with the interaction, a reduction of 0.183 µmol m⁻² s⁻¹ across the held-out plants. Error decreased for seven plants and increased for five.', 'interpretation': 'Origin-specific chilling effects modestly improved average prediction in this sample. Establishing that the gain persists in newly sampled plants requires an independent sample from the target design.', 'assessment': 'The registered result answers the chilling question. The contribution of origin beyond linear CO₂ concentration alone remains untested because that model pair requires separate registration.', 'limitations': ['Each origin-by-treatment group contained three plants, limiting precision despite repeated concentration measurements.', 'The predictive comparison cannot establish a causal effect of origin, and further m"
},
{
"artifact_id": null,
"id": "study:brief-d503a5b597b143dc",
"kind": "study",
"label": "Run a two-part investigation on Potvin's grass plants. First compare a common chilling effect against an origin-specific chilling effect, controlling for log CO2. Then test whether adding origin to linear CO2 concentration alone improves prediction for another plant. Use the registered plant-held-out error in both comparisons. After these two results, identify which claim requires an independent sample.",
"run": "brief-d503a5b597b143dc",
"state": "complete",
"summary": "{'phase': 'abstract', 'title': 'Predicting CO₂ uptake in Potvin’s grass plants with origin-specific chilling effects', 'objective': 'We asked whether allowing the chilling effect to vary by origin improves uptake prediction after adjustment for log CO₂ concentration. A second question asked whether origin improves prediction when linear CO₂ concentration is the sole baseline predictor.', 'methods': 'We compared two prespecified least-squares models on all 84 measurements from 12 plants, holding out each plant in turn and averaging its absolute errors across concentrations before weighting plants equally. Both models included log CO₂ concentration, origin and chilling, and the second added an origin-by-chilling interaction.', 'results': 'Mean absolute error fell from 4.272 to 4.088 µmol m⁻² s⁻¹ with the interaction, a reduction of 0.183 µmol m⁻² s⁻¹ across the held-out plants. Error decreased for seven plants and increased for five.', 'interpretation': 'Origin-specific chilling effects modestly improved average prediction in this sample. Establishing that the gain persists in newly sampled plants requires an independent sample from the target design.', 'assessment': 'The registered result answers the chilling question. The contribution of origin beyond linear CO₂ concentration alone remains untested because that model pair requires separate registration.', 'limitations': ['Each origin-by-treatment group contained three plants, limiting precision despite repeated concentration measurements.', 'The predictive comparison cannot establish a causal effect of origin, and further m"
},
{
"artifact_id": "8f1441a020db01fa066a90f26f2dc7303d44c360c1211c666b923e193e096f6e",
"id": "finding:brief-ae69c3ad445656b3",
"kind": "finding",
"label": "Complete the unresolved reviewer request from brief-4415fb42486d481a: compare CO2 uptake prediction for a held-out plant using conc,origin,chill versus log_conc,origin,chill on the registered Potvin CO2 data. Obtain a trusted potvin_compare receipt for all 12 paired linear-minus-log MAE differences and their equally weighted mean, in µmol m⁻² s⁻¹, with origin and chilling held fixed. Reuse the original accepted evidence through lab_read, label this as same-data reanalysis, and distinguish the already answered original question from this missing adjusted contrast. Do not start unrelated extensions.",
"run": "brief-ae69c3ad445656b3",
"state": "answered",
"summary": "{'phase': 'research_review', 'title': 'Log CO₂ concentration lowered average uptake prediction error for held-out Potvin plants after adjustment for origin and chilling', 'objective': 'The original question asked whether adding geographic origin improved uptake prediction given log CO₂ concentration and chilling. The reviewer asked whether changing the concentration scale improved prediction with origin and chilling in both models.', 'methods': 'The registered potvin_compare runner used the 84 uptake measurements in the R datasets table CO2. Each ordinary least-squares fit held out one whole plant. Both models used a common concentration slope and additive origin and chilling terms. The baseline used conc,origin,chill and the comparison used log_conc,origin,chill. Only the concentration predictor took a natural logarithm. The runner averaged absolute errors on the measured uptake scale across each plant’s seven concentrations, then gave all 12 plants equal weight.', 'results': 'The archived review (finding:brief-3bb15cea899b4e52, citing trial:brief-3bb15cea899b4e52:grass_result.json) reported that adding origin to log_conc,chill lowered mean absolute error (MAE). An earlier concentration-only comparison also favored log concentration (trial:brief-4415fb42486d481a:observation_5.json). In the adjusted same-data reanalysis, equal-plant MAE was 5.119 µmol m⁻² s⁻¹ with linear concentration and 4.272 µmol m⁻² s⁻¹ with log concentration. The runner reported a mean paired reduction of 0.847 µmol m⁻² s⁻¹. The paired differences (linear MAE minus log MAE, µmol m⁻² s⁻¹) were Mc1 -0.32"
},
{
"artifact_id": null,
"id": "study:brief-ae69c3ad445656b3",
"kind": "study",
"label": "Complete the unresolved reviewer request from brief-4415fb42486d481a: compare CO2 uptake prediction for a held-out plant using conc,origin,chill versus log_conc,origin,chill on the registered Potvin CO2 data. Obtain a trusted potvin_compare receipt for all 12 paired linear-minus-log MAE differences and their equally weighted mean, in µmol m⁻² s⁻¹, with origin and chilling held fixed. Reuse the original accepted evidence through lab_read, label this as same-data reanalysis, and distinguish the already answered original question from this missing adjusted contrast. Do not start unrelated extensions.",
"run": "brief-ae69c3ad445656b3",
"state": "complete",
"summary": "{'phase': 'research_review', 'title': 'Log CO₂ concentration lowered average uptake prediction error for held-out Potvin plants after adjustment for origin and chilling', 'objective': 'The original question asked whether adding geographic origin improved uptake prediction given log CO₂ concentration and chilling. The reviewer asked whether changing the concentration scale improved prediction with origin and chilling in both models.', 'methods': 'The registered potvin_compare runner used the 84 uptake measurements in the R datasets table CO2. Each ordinary least-squares fit held out one whole plant. Both models used a common concentration slope and additive origin and chilling terms. The baseline used conc,origin,chill and the comparison used log_conc,origin,chill. Only the concentration predictor took a natural logarithm. The runner averaged absolute errors on the measured uptake scale across each plant’s seven concentrations, then gave all 12 plants equal weight.', 'results': 'The archived review (finding:brief-3bb15cea899b4e52, citing trial:brief-3bb15cea899b4e52:grass_result.json) reported that adding origin to log_conc,chill lowered mean absolute error (MAE). An earlier concentration-only comparison also favored log concentration (trial:brief-4415fb42486d481a:observation_5.json). In the adjusted same-data reanalysis, equal-plant MAE was 5.119 µmol m⁻² s⁻¹ with linear concentration and 4.272 µmol m⁻² s⁻¹ with log concentration. The runner reported a mean paired reduction of 0.847 µmol m⁻² s⁻¹. The paired differences (linear MAE minus log MAE, µmol m⁻² s⁻¹) were Mc1 -0.32"
}
],
"note": "Historical evidence; similarity does not establish equivalent methods or independent replication"
}What evidence does the reviewed finding link to for the change in mean absolute error (MAE) when chilling status is added, both across held-out plants and for each individual plant?
lab_read · ok
{
"body": {
"artifact_id": "f5d2662fa37771ac133c3078a26dbc18b0b3543b911a872e9c4e1f3cec804ced",
"artifact_sha256": "058077d6a009bea69b2b3bc60bb750ac7aa90bdb71416875b264c994071818d3",
"evidence_level": "independent reviewer assessment",
"run": "brief-330b53f6935349cc",
"summary": {
"assessment": "The registered comparison covered every audited plant and all 84 uptake measurements.",
"continue_on_current_data": true,
"disposition": "accept",
"evidence_artifact_ids": [
"06f86d7a7c5c2679007d1ca0dc477f90f6179bc7f5a95d10053f6de8159cdc0a",
"49a70752c8ed50fa6c348f014d00c5a6f9c75456817bde6e46467401292c4d7d",
"79bed7244f434371649d6e9fcbacf2526db9638fff9a9a24dc889f58d3aca3ea",
"c9110e613fcc2680551a8f5a122ecb73e6197a3ea36a3eef7833c781ded63716",
"fe761ab3273141efba4d3d95d66af442442d203b430d98db39df401bc90c5fa0"
],
"interpretation": "Chilling status improved uptake predictions on average within the Potvin design. All three plants with larger errors came from Quebec, suggesting that a shared chilling term may fit the two origins differently.",
"limitations": [
"With three plants per origin and treatment combination, the gain is imprecisely estimated and its generalizability requires an independent cohort. This predictive comparison cannot establish a causal effect of chilling."
],
"methods": "Holding out one whole plant at a time, the registered analysis fitted unweighted ordinary least squares models with an intercept, origin and log CO₂ concentration, then repeated each fit with a shared additive chilling term. We compared mean absolute error (MAE) across the seven concentrations for each held-out plant and weighted plants equally.",
"next_question": "On the same whole-plant holdouts, does adding an origin-by-chilling interaction to the additive model further reduce equal-plant MAE in an exploratory comparison?",
"objective": "We asked whether chilling status improves prediction of a plant’s CO₂ uptake after accounting for its origin and the natural logarithm of CO₂ concentration.",
"phase": "abstract",
"requested_operations": [],
"results": "Adding chilling status reduced mean MAE from 5.346 to 4.272 µmol m⁻² s⁻¹, a paired reduction of 1.075 µmol m⁻² s⁻¹. MAE fell for 9 of 12 plants and rose most for Qc2, from 3.914 to 6.211 µmol m⁻² s⁻¹, an increase of 2.297 µmol m⁻² s⁻¹.",
"title": "Chilling status improved average CO₂ uptake predictions for held-out Potvin grass plants"
}
},
"edges": [
{
"relation": "concluded",
"source": "study:brief-330b53f6935349cc",
"target": "finding:brief-330b53f6935349cc"
},
{
"relation": "reviews",
"source": "finding:brief-330b53f6935349cc",
"target": "trial:brief-330b53f6935349cc:catalogue.json"
},
{
"relation": "reviews",
"source": "finding:brief-330b53f6935349cc",
"target": "trial:brief-330b53f6935349cc:grass_audit.json"
},
{
"relation": "reviews",
"source": "finding:brief-330b53f6935349cc",
"target": "trial:brief-330b53f6935349cc:grass_result.json"
}
],
"id": "finding:brief-330b53f6935349cc",
"kind": "finding",
"label": "In the Potvin grass dataset, does knowing whether a plant was chilled improve CO₂ uptake predictions after accounting for its origin and log CO₂ concentration? Hold out one whole plant at a time. Report how many plants benefited and identify the plant whose prediction got worse by the largest amount.",
"state": "reviewed",
"updated": 1795037128.014529
}Does the reviewed trial answer the original brief about average prediction error, the number of plants that benefited and the largest individual error increase?
finish · ok
{}What does the reviewed Potvin trial report about the change in held-out uptake prediction error when the chilling effect can differ between Quebec and Mississippi?
lab_read · ok
{
"body": {
"artifact_id": "4b00f2fc4011cd799caa6efe0bc81224c4ac172041d0bf06ae6f7892701c6bc4",
"artifact_sha256": "6bc5bd4cfb95e8abdc23ed67db273b269474c2188503787aa4d06607ac634c02",
"evidence_level": "independent reviewer assessment",
"run": "brief-d503a5b597b143dc",
"summary": {
"assessment": "The registered result answers the chilling question. The contribution of origin beyond linear CO₂ concentration alone remains untested because that model pair requires separate registration.",
"continue_on_current_data": false,
"disposition": "accept",
"evidence_artifact_ids": [
"2dbd8ec6b89dc24c22b709c6805fc6f3a5316173d4769a5d6df369b436401971",
"6d929ce087a67cd09a55591981c58c7c919ccb39d060db2b5a24643a37c414ac",
"c38451e477d587b32d8f0e13e34a17d6ddf696e60b8dcb0cf16a92024a350e28",
"10c7b05b31cfa1a4d49ba96862c842f8774e1b17974312187a70b143f6bc7515",
"ecdd2ca0406e3f8cbb1372d4489c4e3666ecd06d5a846dee235c6a85e4c37afa"
],
"interpretation": "Origin-specific chilling effects modestly improved average prediction in this sample. Establishing that the gain persists in newly sampled plants requires an independent sample from the target design.",
"limitations": [
"Each origin-by-treatment group contained three plants, limiting precision despite repeated concentration measurements.",
"The predictive comparison cannot establish a causal effect of origin, and further model selection on these folds would be exploratory."
],
"methods": "We compared two prespecified least-squares models on all 84 measurements from 12 plants, holding out each plant in turn and averaging its absolute errors across concentrations before weighting plants equally. Both models included log CO₂ concentration, origin and chilling, and the second added an origin-by-chilling interaction.",
"next_question": "In an independent sample of Mississippi and Quebec plants measured under the same chilling treatments and CO₂ concentrations, what equal-plant mean absolute error does the interaction model achieve with its coefficients fixed before testing?",
"objective": "We asked whether allowing the chilling effect to vary by origin improves uptake prediction after adjustment for log CO₂ concentration. A second question asked whether origin improves prediction when linear CO₂ concentration is the sole baseline predictor.",
"phase": "abstract",
"requested_operations": [],
"results": "Mean absolute error fell from 4.272 to 4.088 µmol m⁻² s⁻¹ with the interaction, a reduction of 0.183 µmol m⁻² s⁻¹ across the held-out plants. Error decreased for seven plants and increased for five.",
"title": "Predicting CO₂ uptake in Potvin’s grass plants with origin-specific chilling effects"
}
},
"edges": [
{
"relation": "concluded",
"source": "study:brief-d503a5b597b143dc",
"target": "finding:brief-d503a5b597b143dc"
},
{
"relation": "reviews",
"source": "finding:brief-d503a5b597b143dc",
"target": "trial:brief-d503a5b597b143dc:grass_audit.json"
},
{
"relation": "reviews",
"source": "finding:brief-d503a5b597b143dc",
"target": "trial:brief-d503a5b597b143dc:grass_result.json"
}
],
"id": "finding:brief-d503a5b597b143dc",
"kind": "finding",
"label": "Run a two-part investigation on Potvin's grass plants. First compare a common chilling effect against an origin-specific chilling effect, controlling for log CO2. Then test whether adding origin to linear CO2 concentration alone improves prediction for another plant. Use the registered plant-held-out error in both comparisons. After these two results, identify which claim requires an independent sample.",
"state": "reviewed",
"updated": 1795037128.2754402
}Which columns and factor levels in the registered Potvin CO2 table identify each plant, its origin and chilling treatment, the CO₂ concentration and the measured uptake?
table · ok
{
"collection": "R datasets",
"columns": [
"rownames",
"Plant",
"Type",
"Treatment",
"conc",
"uptake"
],
"filename": "CO2.csv",
"levels": {
"Plant": [
"Qn1",
"Qn2",
"Qn3",
"Qc1",
"Qc2",
"Qc3",
"Mn1",
"Mn2",
"Mn3",
"Mc1",
"Mc2",
"Mc3"
],
"Treatment": [
"nonchilled",
"chilled"
],
"Type": [
"Quebec",
"Mississippi"
],
"conc": [
"95",
"175",
"250",
"350",
"500",
"675",
"1000"
]
},
"raw_sha256": "0c16fc00f276b0981a0d9f8800de62524acda32f66d7a0f7b96e0806c04a7b29",
"rows": 84,
"table_sha256": "a24abfa3686f7489a84845b4d6823e08af21f5f94b6455404bbdbbe2f22e7571",
"url": "https://raw.githubusercontent.com/vincentarelbundock/Rdatasets/cc03c29690889dbe83089f5206e2422db8c3f71f/csv/datasets/CO2.csv"
}How does allowing the chilling effect to vary between Quebec and Mississippi change uptake prediction error for each held-out plant and on average across plants?
potvin_compare · ok
{
"features": [
[
"log_conc",
"origin",
"chill"
],
[
"log_conc",
"origin",
"chill",
"origin_chill"
]
],
"fits": 24,
"limitations": "Small public dataset, two origins with three plants per origin-treatment cell. All rounds reuse the same grouped folds. Adaptive selection makes later results exploratory. No independent final test, causal claim, or independent replication of the sunflower result.",
"mae": {
"augmented": 4.088129116031577,
"baseline": 4.271539387545705,
"improvement": 0.18341027151412806
},
"per_plant": [
{
"augmented": 3.9675586016135016,
"baseline": 2.8469308577175942,
"improvement": -1.1206277438959074,
"plant": "Mc1"
},
{
"augmented": 5.929032742992036,
"baseline": 7.080952380952391,
"improvement": 1.1519196379603551,
"plant": "Mc2"
},
{
"augmented": 4.536519277393226,
"baseline": 4.188900229774185,
"improvement": -0.34761904761904105,
"plant": "Mc3"
},
{
"augmented": 2.2975486147165114,
"baseline": 3.495261673537706,
"improvement": 1.1977130588211944,
"plant": "Mn1"
},
{
"augmented": 3.6846226048143764,
"baseline": 4.495644619651655,
"improvement": 0.8110220148372784,
"plant": "Mn2"
},
{
"augmented": 3.3834720074358704,
"baseline": 2.7086673708808022,
"improvement": -0.6748046365550682,
"plant": "Mn3"
},
{
"augmented": 3.1815443151337592,
"baseline": 2.1175987369024756,
"improvement": -1.0639455782312837,
"plant": "Qc1"
},
{
"augmented": 4.762488616811713,
"baseline": 6.210901315224397,
"improvement": 1.4484126984126835,
"plant": "Qc2"
},
{
"augmented": 4.334929609566613,
"baseline": 5.212140493920346,
"improvement": 0.8772108843537332,
"plant": "Qc3"
},
{
"augmented": 3.5618394034945333,
"baseline": 4.992063492063505,
"improvement": 1.430224088568972,
"plant": "Qn1"
},
{
"augmented": 3.8275778514348153,
"baseline": 4.093065856402089,
"improvement": 0.26548800496727365,
"plant": "Qn2"
},
{
"augmented": 5.590415746971957,
"baseline": 3.816345623521304,
"improvement": -1.7740701234506533,
"plant": "Qn3"
}
],
"plants": 12,
"rows": 84,
"unit": "µmol m⁻² s⁻¹"
}Does the completed whole-plant comparison resolve how much each plant contributed to the change in prediction error when chilling effects were allowed to vary by origin?
finish · ok
{}Artifact references
abstract.json726b1cf137d81c9cb6d1a34bb397861d926fd2a26dc4404396bcad5347c75e36
brief.json332bd5c86821c63fa74728ff34b85d7690a38a810500831f20c1188892b1c56f
extension.json3490ac48c8e54c5f48221167f434f7c1f0e8a7cc7410b6474b10ce4943a8b528
observation_1.json757d235504216d1088f7dc7829d7bbeb47d1893f092027cebca08ce9ed445623
observation_2.json91ba3839790aae78f3a032941098771729629ea15cb07786c48f0040bdac5048
observation_3.json6c32545cced1aa134a1ec3578c73258136e0732716baa76d455332fc963628bf
observation_4.json536cf37e1e33c6dcf1e595ef5350cc5656ee31a0ff72f485ab069e4f438b5748
observation_5.json621ffc7eca11ad4d257cb7fd3f1ebe782d14389ed1f61f85380b146f67a19f6a
observation_6.jsonef4eaed133abbed253d86a13bd3e18e26e669ab0ab14ba3249ce3da83bb29ba8
observation_7.jsone9db4d3ddf4e019f09c76397ea254ae0273051ab95e8f677dda88c662d04f2de
research_plan.jsondbe0ad0c5261db0435dd143781f5cd1736286b93a38bf2c3a39ad7f82836cdc4
Verified against 19 accepted tasks, 10 verified Codex turns and 0 estimator fits.